Photoreceiver efficiency measurementsThe efficiency and other related parameters of Smithsonian Astrophysical Observatory's four laser receivers were measured at the observing stations by oscilloscope photography. If the efficiency is defined as the number of photoelectrons generated by the photomultiplier tube divided by the number of photons entering the aperture of the receiver, its measured value is about 1% for the laser wavelength of 694 nm. This value is consistent with the efficiency computed from the specified characteristics of the photoreceiver's optical components.
Document ID
19750007903
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Lehr, C. G.
(Smithsonian Astrophysical Observatory Cambridge, MA, United States)
Date Acquired
September 3, 2013
Publication Date
January 1, 1975
Subject Category
Lasers And Masers
Report/Patent Number
SAO-LASER-REPT-6
NASA-CR-142070
Report Number: SAO-LASER-REPT-6
Report Number: NASA-CR-142070
Accession Number
75N15975
Funding Number(s)
CONTRACT_GRANT: NGR-09-015-002
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.