NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Optimization of contaminated oxide inversion layer solar cellContaminated oxide cells have been fabricated with efficiencies of 8.6% with values of I sub sc = 120 ma, V sub oc = .54 volts, and curve factor of .73. Attempts to optimize the fabrication step to yield a higher output have not been successful. The fundamental limitation is the inadequate antireflection coating afforded by the silicon dioxide coating used to hold the contaminating ions. Coatings of SiO, therefore, were used to obtain a good antireflection coating, but the thinness of the coatings prevented a large concentration of the contaminating ions, and the cells was weak. Data of the best cell were .52 volts V sub oc, 110 ma I sub sc, .66 CFF and 6.7% efficiency.
Document ID
19760018567
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Call, R. L.
(Arizona Univ. Tucson, AZ, United States)
Date Acquired
September 3, 2013
Publication Date
April 1, 1976
Subject Category
Energy Production And Conversion
Report/Patent Number
NASA-CR-148150
Report Number: NASA-CR-148150
Accession Number
76N25655
Funding Number(s)
CONTRACT_GRANT: JPL-954189
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available