NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Some studies on a solid state sulfur probe for coal gasification systemsMeasurements on the solid electrolyte cell (Ar + H(2) + H(2)S/CaS + CaF(2) + (Pt)//CaF(2)//(Pt) + CaF(2) + CaS/H(2) + H(2)+Ar) show that the emf of the cell is directly related to the difference in sulfur potentials established at the Ar + H(2) + H(2)S/electrode interfaces. The electrodes convert the sulfur potential gradient across the calcium fluoride electrolyte into an equivalent fluorine potential gradient. Response time of the probe varies from approximately 9 hr at 990 K to 2.5 hr at 1225 K. The conversion of calcium sulfide and/or calcium fluoride into calcium oxide is not a problem anticipated in commercial coal gasification systems. Suggestions are presented for improving the cell for such commercial applications.
Document ID
19770024661
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Jacob, K. T.
(California Univ. Berkeley, United States)
Rao, D. B.
(NASA Ames Research Center Moffett Field, CA, United States)
Nelson, H. G.
(NASA Ames Research Center Moffett Field, CA, United States)
Date Acquired
September 3, 2013
Publication Date
August 1, 1977
Subject Category
Energy Production And Conversion
Report/Patent Number
A-7162
NASA-TM-78428
Report Number: A-7162
Report Number: NASA-TM-78428
Accession Number
77N31605
Funding Number(s)
PROJECT: RTOP 778-11-02
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.