NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Evaluation of three thermal protection systems in a hypersonic high-heating-rate environment induced by an elevon deflected 30 degThree thermal protection systems proposed for a hypersonic research airplane were subjected to high heating rates in the Langley 8 foot, high temperature structures tunnel. Metallic heat sink (Lockalloy), reusable surface insulation, and insulator-ablator materials were each tested under similar conditions. The specimens were tested for a 10 second exposure on the windward side of an elevon deflected 30 deg. The metallic heat sink panel exhibited no damage; whereas the reusable surface insulation tiles were debonded from the panel and the insulator-ablator panel eroded through its thickness, thus exposing the aluminum structure to the Mach 7 environment.
Document ID
19780007084
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Taylor, A. H.
(Vought Corp. Hampton, Va., United States)
Jackson, L. R.
(NASA Langley Research Center Hampton, VA, United States)
Weinstein, I.
(NASA Langley Research Center Hampton, VA, United States)
Date Acquired
September 3, 2013
Publication Date
December 1, 1977
Subject Category
Aircraft Design, Testing And Performance
Report/Patent Number
NASA-TM-74077
L-11734
Report Number: NASA-TM-74077
Report Number: L-11734
Accession Number
78N15027
Funding Number(s)
PROJECT: RTOP 505-11-31-02
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available