NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Calibration analysis for a multi-channel infrared scanning radiometerA procedure for calibrating an infrared scanning spectroradiometer by a computerized parametric error analysis technique was developed. The uncertainties in the radiometric measurements of scene radiance and (for the case of a blackbody scene) temperature due to possible uncertainties in the calibration target temperature, calibration target emissivity, and instrument temperature were calculated for a range of uncertainty levels in the parameters, as well as for a gamut of scent temperatures corresponding to a given spectral channel. This technique is applicable to the radiometric calibration of any infrared radiometer. It was applied specifically to the Cloud-Top Scanning (C.T.S) Radiometer, a three-channel instrument designed for aircraftborne cloud radiance measurements in the 6.75 and 11.5 micron thermal emission spectral regions.
Document ID
19780015960
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Walden, H.
(NASA Goddard Space Flight Center Greenbelt, MD, United States)
Hurley, E. J.
(NASA Goddard Space Flight Center Greenbelt, MD, United States)
Korb, C. L.
(NASA Goddard Space Flight Center Greenbelt, MD, United States)
Date Acquired
September 3, 2013
Publication Date
December 1, 1977
Subject Category
Optics
Report/Patent Number
NASA-TM-78058
Report Number: NASA-TM-78058
Accession Number
78N23903
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.