MSFC Assessment of Owens-Illinois SUNPAK Collector ProblemsAn in-depth assessment is presented of problems encountered with the Owens-Illinois SUNPAK collector installed in several ERDA solar system demonstration sites. Analysis and independent tests of the collector in the MSFC Solar Simulator where the system failure conditions were duplicated are included. The basic design of the SUNPAK collector was shown to be sound; however, material limitations dictate that near-term applications constraints be recognized by system designers. MSFC recommendations were presented to ERDA in March 1977. Subsequent retrofit activity by Owens-Illinois appears to have been effective in demonstrating the integrity of the SUNPAK collector.