Water system microbial check valve developmentA residual iodine microbial check valve (RIMCV) assembly was developed and tested. The assembly is designed to be used in the space shuttle potable water system. The RIMCV is based on an anion exchange resin that is supersaturated with an iodine solution. This system causes a residual to be present in the effluent water which provides continuing bactericidal action. A flight prototype design was finalized and five units were manufactured and delivered.
Document ID
19790003562
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Colombo, G. V.
(Umpqua Research Co. Myrtle Creek, OR, United States)
Greenley, D. R.
(Umpqua Research Co. Myrtle Creek, OR, United States)
Putnam, D. F.
(Umpqua Research Co. Myrtle Creek, OR, United States)
Date Acquired
September 3, 2013
Publication Date
July 1, 1978
Subject Category
Man/System Technology And Life Support
Report/Patent Number
URC-80708
NASA-CR-151843
Report Number: URC-80708
Report Number: NASA-CR-151843
Accession Number
79N11733
Funding Number(s)
CONTRACT_GRANT: NAS9-15079
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.