Smoke toxicity methodologyThe toxicity of pyrolysis products for aircraft interior materials must be within some reasonable limit. The toxicity of pyrolysis products from five candidate aircraft materials is evaluated. The most important part of this study was to demonstrate that pyrolysis of materials could be controlled and biological endpoints are reproducible.
Document ID
19790003867
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Dilley, J. V.
(SRI International Corp. Menlo Park, CA, United States)
Martin, S. B.
(SRI International Corp. Menlo Park, CA, United States)
Mckee, R.
(SRI International Corp. Menlo Park, CA, United States)
Pryor, G.
(SRI International Corp. Menlo Park, CA, United States)
Date Acquired
August 10, 2013
Publication Date
October 1, 1978
Publication Information
Publication: NASA. Ames Res. Center Conf. on Fire Resistant Mater. (FIREMEN)
Subject Category
Air Transportation And Safety
Accession Number
79N12038
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available