Back to Results
Atlas 5013 tank corrosion testThe type and cause of corrosion in spot welded joints were determined by X-ray and chemical analysis. Fatigue and static tests showed the degree of degradation of mechanical properties. The corrosion inhibiting effectiveness of WD-40 compound and required renewal period by exposing typical joint specimens were examined.
Document ID
19790019063
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Sutherland, W. M.
(General Dynamics/Convair San Diego, CA, United States)
Girton, L. D.
(General Dynamics/Convair San Diego, CA, United States)
Treadway, D. G.
(General Dynamics/Convair San Diego, CA, United States)
Date Acquired
September 3, 2013
Publication Date
December 1, 1978
Subject Category
Spacecraft Design, Testing And Performance
Report/Patent Number
NASA-CR-158760
CASD-LVP-78-078
Report Number: NASA-CR-158760
Report Number: CASD-LVP-78-078
Accession Number
79N27234
Funding Number(s)
CONTRACT_GRANT: NAS3-20644
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available