Full-coverage film cooling on flat, isothermal surfaces: Data and predictionsThe heat transfer and fluid mechanics characteristics of full-coverage film cooling were investigated. The results for flat, isothermal plates for three injection geometries (normal, slant, and compound angle) are summarized and data concerning the spanwise distribution of the heat transfer coefficient within the blowing region are presented. Data are also presented for two different numbers of rows of holes (6 and 11). The experimental results summarized can be predicted with a two dimensional boundary layer code, STANCOOL, by providing descriptors of the injection parameters as inputs.