A spectral filter for ESMR's sidelobe errorsFourier analysis was used to remove periodic errors from a series of NIMBUS-5 electronically scanned microwave radiometer brightness temperatures. The observations were all taken from the midnight orbits over fixed sites in the Australian grasslands. The angular dependence of the data indicates calibration errors consisted of broad sidelobes and some miscalibration as a function of beam position. Even though an angular recalibration curve cannot be derived from the available data, the systematic errors can be removed with a spectral filter. The 7 day cycle in the drift of the orbit of NIMBUS-5, coupled to the look-angle biases, produces an error pattern with peaks in its power spectrum at the weekly harmonics. About plus or minus 4 K of error is removed by simply blocking the variations near two- and three-cycles-per-week.
Document ID
19800008142
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Chesters, D.
(NASA Goddard Space Flight Center Greenbelt, MD, United States)
Date Acquired
September 4, 2013
Publication Date
September 1, 1979
Subject Category
Earth Resources And Remote Sensing
Report/Patent Number
NASA-TM-80555
Report Number: NASA-TM-80555
Accession Number
80N16402
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available