NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Heating rate measurements over 30 deg and 40 deg (half angle) blunt cones in air and helium in the Langley expansion tube facilityConvective heat transfer measurements, made on the conical portion of spherically blunted cones (30 deg and 40 deg half angle) in an expansion tube are discussed. The test gases used were helium and air; flow velocities were about 6.8 km/sec for helium and about 5.1 km/sec for air. The measured heating rates are compared with calculated results using a viscous shock layer computer code. For air, various techniques to determine flow velocity yielded identical results, but for helium, the flow velocity varied by as much as eight percent depending on which technique was used. The measured heating rates are in satisfactory agreement with calculation for helium, assuming the lower flow velocity, the measurements are significantly greater than theory and the discrepancy increased with increasing distance along the cone.
Document ID
19800014145
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Reddy, N. M.
(NASA Langley Research Center Hampton, VA, United States)
Date Acquired
September 4, 2013
Publication Date
March 1, 1980
Subject Category
Fluid Mechanics And Heat Transfer
Report/Patent Number
NASA-TM-80207
Report Number: NASA-TM-80207
Accession Number
80N22632
Funding Number(s)
PROJECT: RTOP 506-51-23-01
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available