NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Solar energy system performance evaluation report for Solaron-Duffield, Duffield, VirginiaThe Solaron Duffield Solar Energy System was designed to provide 51 percent of the space heating, and 49 percent of the domestic hot water (DHW) to a two story 1940 square foot area residence using air as the transport medium. The system consists of a 429 square foot collector array, a 265 cubic foot rock thermal storage bin, heat exchangers, an 80 gallon DHW preheat tank, pumps, blowers, controls, air ducting and associated plumbing. A air-to-liquid heat pump coupled with a 1,000gallon water storage tank provides for auxiliary space heating and can also be used for space cooling. A 52 gallon electric DHW tank using the solar preheated water provides domestic hot water to the residence. The solar system, which became operational July 1979, has the following modes of operation: First Stage: (1) collector to storage and DHW; (2)collector to space heating; (3) storage to load. Second Stage: (4) heat pump auxiliary direct; (5) auxiliary heat from heat pump storage. Third Stage: (6) electrical resistance (strip) heat.
Document ID
19800022387
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Date Acquired
September 4, 2013
Publication Date
July 1, 1980
Subject Category
Energy Production And Conversion
Report/Patent Number
NASA-CR-161507
Report Number: NASA-CR-161507
Accession Number
80N30892
Funding Number(s)
CONTRACT_GRANT: NAS8-32036
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available