NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Comparison of different plate treatments and designs, an updateNine packs of cells of different designs were put on test at Crane. They were run through their initial evaluation tests and then put into a cycling test. These were GE 12A h cells. The temperature was 20 C, the orbit was 90 minutes, the depth of discharge was 40%, the discharge rate was 9.6A and the initial charge rate was 9.6A to a voltage limit where it went into a taper. The goal was to get 100% return. The voltage limit was 1.453V through most of the testing, although recently it became necessary to lower some packs and raise some to hold 115% return. After one year, one cell from each pack was removed and the initial evaluation tests were repeated.
Document ID
19810012996
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Baer, D.
(NASA Goddard Space Flight Center Greenbelt, MD, United States)
Date Acquired
August 11, 2013
Publication Date
March 1, 1981
Publication Information
Publication: The 1980 Goddard Space Flight Center Battery Workshop
Subject Category
Energy Production And Conversion
Accession Number
81N21525
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.

Available Downloads

There are no available downloads for this record.