NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Discharge of 1400 AH lithium thionyl chloride cells into voltage reversalThe development of a high energy density battery is discussed. Tests were conducted on a 1400 AH cell and they include: drop tests, crush tests, vibration and shock tests, hydrostatic pressure effects, charge current tests, and discharge tests. None of these tests led to a venting or explosion of the cell. Criteria are presented for extending RV safety of a 1400 AH cell.
Document ID
19820012535
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Zolla, A. E.
(Altus Corp. San Jose, CA, United States)
Date Acquired
August 10, 2013
Publication Date
March 1, 1982
Publication Information
Publication: NASA. Goddard Space Flight Center The 1981 GSFC Battery Workshop
Subject Category
Electronics And Electrical Engineering
Accession Number
82N20409
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.

Available Downloads

There are no available downloads for this record.
No Preview Available