Comparisons of different plate treatment and designs: An updateNine groups of cells were studied. The first group was the control. The basic design was cadmium in the positive plate, and no negative treatment. The plate loading level was the IUE. The separator was pellon. The test regime for the remaining cells was a 90 minute cycle with 40% depth of discharge and a temperature of 20 C. The charge rate was 9.6 amps to a voltage limit. The discharge rate was 9.6 amps.