Clocks for airborne systemsThe potential performance of compact oscillators, needed for the development of accurate clocks for future airborne systems (such as Identification Friend or Foe schemes), is addressed. In particular, extensive testing of rubidium oscillators manufactured by Efratom is discussed. The results indicate that an accuracy of better than 10 microseconds should be achievable in tactical aircraft provided that appropriate measures are adopted to counter the many environmental factors. In a favorable environment a stability of better than 5 x 10 to the -13th power for one day is achievable with present commercial units, but improvements are required to suit operation in an aircraft. With further development of rubidium controlled clocks the ultimate limitation on time accuracy in aircraft will probably be associated with time dissemination, maintenance difficulties and doctrinal hurdles.
Document ID
19820012644
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Houlding, N.
(Mitre Corp. Bedford, MA, United States)
Date Acquired
August 10, 2013
Publication Date
March 1, 1982
Publication Information
Publication: NASA. Goddard Space Flight Center Proc. of the 13th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting
Subject Category
Lasers And Masers
Accession Number
82N20518
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.