NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Development of design allowable data for Celion 6000/LARC-160, graphite/polyimide composite laminatesA design allowables test program was conducted on Celion 6000/LARC-160 graphite polyimide composite to establish material performance over a 116 K (-250 F) to 589 K (600 F) temperature range. Tension, compression, in-plane shear and short beam shear properties were determined for uniaxial, quasi-isotropic and + or - 45 deg laminates. Effects of thermal aging and moisture saturation on mechanical properties were also evaluated. Celion 6000/LARC-160 graphite/polyimide can be considered an acceptable material system for structural applications to 589 K (600 F).
Document ID
19830008120
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Ehret, R. M.
(Rockwell International Corp. Los Angeles, CA, United States)
Scanlan, P. R.
(Rockwell International Corp. Los Angeles, CA, United States)
Rosen, C. D.
(Rockwell International Corp. Los Angeles, CA, United States)
Date Acquired
September 4, 2013
Publication Date
November 1, 1982
Subject Category
Composite Materials
Report/Patent Number
NAS 1.26:165985
NASA-CR-165985
Report Number: NAS 1.26:165985
Report Number: NASA-CR-165985
Accession Number
83N16391
Funding Number(s)
CONTRACT_GRANT: NAS1-15183
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available