NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Stable and rugged etalon for the Dynamics Explorer Fabry-Perot interferometer. II - PerformanceThe etalon is shown to remain stable to less than 5-m/sec equivalent wind over one orbit and less than 100 m/sec over several months in orbit. The thermal stability considerations for the highly stable etalon are discussed, including the passive thermal control used in flight. The various physical processes which give rise to drifts in the peak transmission wavelength are quantified, and the kinematic mount used to isolate the etalon from large incremental forces caused by changes in the thermal environment is presented. The performance of the etalon in its flight configuration is evaluated.
Document ID
19830031095
Acquisition Source
Legacy CDMS
Document Type
Reprint (Version printed in journal)
Authors
Killeen, T. L.
(Michigan Univ. Ann Arbor, MI, United States)
Hays, P. B.
(Michigan Univ. Ann Arbor, MI, United States)
Kennedy, B. C.
(Michigan, University Ann Arbor, MI, United States)
Rees, D.
(University College London, United Kingdom)
Date Acquired
August 11, 2013
Publication Date
November 1, 1982
Publication Information
Publication: Applied Optics
Volume: 21
Subject Category
Spacecraft Instrumentation
Accession Number
83A12313
Funding Number(s)
CONTRACT_GRANT: NAS5-24296
Distribution Limits
Public
Copyright
Other

Available Downloads

There are no available downloads for this record.