Dynamic distortion in a short s-shaped subsonic diffuser with flow separationAn experimental investigation of the time varying distortion at the diffuser exit of a subsonic HiMAT forebody and inlet was conducted at Mach 0.9 in the Lewis 8 by 6 foot Supersonic Wind Tunnel. A transitory separation was detected within the subsonic diffuser. Vortex generators were installed to eliminate the flow separation. Results from a study of the instantaneous pressure variations at the diffuser exit are presented. The time unsteady total pressures at the diffuser exit are computer interpolated and presented in the form of a movie showing the transitory separation. Limited data showing the instantaneous distortion levels are also presented. Previously announced in STAR as N83-26838
Document ID
19830064297
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Stumpf, R. (NASA Lewis Research Center Cleveland, OH, United States)
Neumann, H. E. (NASA Lewis Research Center Cleveland, OH, United States)
Giamati, C. C. (NASA Lewis Research Center Cleveland, OH, United States)
Date Acquired
August 11, 2013
Publication Date
June 1, 1983
Subject Category
Aircraft Propulsion And Power
Report/Patent Number
AIAA PAPER 83-1412Report Number: AIAA PAPER 83-1412