NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Columbia: The first 5 flights entry heating data series. Volume 5: The side fuselage and payload bay doorEntry heating flight data and wind tunnel data on the side fuselage and payload bay door, Z = 400 and 440 trace aft of X/L=0.2, for the first five flights of the Space Shuttle Orbiter are presented. The heating rate data are reviewed in terms of normalized film heat transfer coefficients as a function of angle of attack, Mach number, and normal shock Reynolds number. The surface heatings rates and temperatures were obtained by the JSC NONLIN/INVERSE computer program. Time history plots of the surface heating rates and temperatures are outlined.
Document ID
19840024346
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Williams, S. D.
(Lockheed Engineering and Management Services Co., Inc. Houston, TX, United States)
Date Acquired
September 4, 2013
Publication Date
January 1, 1984
Subject Category
Space Transportation
Report/Patent Number
NAS 1.26:171732
LEMSCO-19346-VOL-5
NASA-CR-171732
Report Number: NAS 1.26:171732
Report Number: LEMSCO-19346-VOL-5
Report Number: NASA-CR-171732
Accession Number
84N32416
Funding Number(s)
CONTRACT_GRANT: NAS9-15800
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.