NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Heat Transfer Characteristics of Regenerator Matrix (Case of Packed Wire Gauzes)The average heat transfer coefficient in the matrix of laminated wire screens (10 to 250 mesh) for a Stirling engine heat exchanger was studied experimentally. The data are correlated by N sub ud = 0.42 R sub ed 0.56 (3 or = R sub ed or = 400), and R sub ed are the Nusselt and Reynolds nubmers based on the wire diameter. The pressure drop decreased and the heat transfer increased as the wire diameter was decreased.