Thermal aging of graphite/polyimide compositesCelion 6000/PMR-15, Celion 6000/LARC-160, and Celion 6000/RK-99 graphite/polyimides were aged in circulating air ovens at temperatures of 202, 232, 260, and 288 C for various times, up to 15,000 h. Three unidirectional specimens were studied: short-beam-shear (SBS), flexure, and 153-mm square panels. The interior region of the square panels exhibited little or no property degradation. Based on the individually aged SBS specimen results, the relative thermal-oxidative stability from highest to lowest is as follows: PMR-15, LARC-160, RK-99, Celion 6000/PMR-15 and Celion 6000/LARC-160 laminates retained at least 80 percent of their initial flexural strengths for the duration of aging at each temperature. Celion 6000/RK-99 laminates exhibited a 20 to 50 percent loss of flexural strength at all aging temperatures. All three graphite/polyimide laminate materials degraded preferentially at the specimen edge perpendicular to the fibers.
Document ID
19840042101
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Nelson, J. B. (NASA Langley Research Center Hampton, VA, United States)