Two-phase turbine stagingTwo-phase turbines would be useful in Rankine cycles using low-quality or saturated-liquid working fluids. The chief problem is low efficiency due to slip losses in nozzles and due to liquid impact and friction losses in rotors. To raise efficiency, a staging method was tested in which the first stage operated at high speed with low relative liquid velocity, and the second stage recovered the first-stage exit energy. The theoretical efficiency for an experimental turbine operating with Refrigerant-22 was raised from 55 percent to 66 percent, and the measured efficiency was raised from 52 percent to 57 percent.