Two-phase turbine stagingTwo-phase turbines would be useful in Rankine cycles using low-quality or saturated-liquid working fluids. The chief problem is low efficiency due to slip losses in nozzles and due to liquid impact and friction losses in rotors. To raise efficiency, a staging method was tested in which the first stage operated at high speed with low relative liquid velocity, and the second stage recovered the first-stage exit energy. The theoretical efficiency for an experimental turbine operating with Refrigerant-22 was raised from 55 percent to 66 percent, and the measured efficiency was raised from 52 percent to 57 percent.
Document ID
19840047281
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Elliott, D. G. (California Institute of Technology, Jet Propulsion Laboratory, Pasadena CA, United States)