NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Shower disc sampling and the angular resolution of gamma-ray shower detectorsAs part of the design study for the new UHE gamma ray detector being constsructed at Haverah Park, a series of experiments using scintillators operated side-by-side in 10 to the 15th power eV air showers are undertaken. Investigation of the rms sampling fluctuations in the shower disc arrival time yields an upper limit to the intrinsic sampling uncertainty, sigma sub rms = (1.1 + or - 0.1)ns, implying an angular resolution capability 1 deg for an inter-detector spacing of approximately 25 m.
Document ID
19850026667
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Lambert, A.
(Leeds Univ.)
Lloyd-Evans, J.
(Leeds Univ.)
Date Acquired
August 12, 2013
Publication Date
August 1, 1985
Publication Information
Publication: 19th Intern. Cosmic Ray Conf - Vol. 3
Subject Category
Space Radiation
Report/Patent Number
OG-9.5-2
Accession Number
85N34980
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available