Results of variable enthalpy tests of CPR-488 TIP panels in MSFC Hot Gas FacilityTests were conducted to determine the effects of variable enthalpy levels on CPR-488 foam performance and/or recession. Also to be determined was whether the BX-250 thickness indicator plugs (TIP) concept is feasible for measuring recession rates of CPR-488 foam during external tank flight. The tests determined that the TIP plug idea works. The accuracy of the indicated recession depth is approximately + or - 1.16 in. The BX-250 plugs with TiO2 work better than the regular BX-250 plugs. Also, there is an effect of enthalpy on CPR-488 foam performance.