NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Total integrated dose testing of solid-state scientific CD4011, CD4013, and CD4060 devices by irradiation with CO-60 gamma raysThe total integrated dose response of three CMOS devices manufactured by Solid State Scientific has been measured using CO-60 gamma rays. Key parameter measurements were made and compared for each device type. The data show that the CD4011, CD4013, and CD4060 produced by this manufacturers should not be used in any environments where radiation levels might exceed 1,000 rad(Si).
Document ID
19850027482
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Dantas, A. R. V.
(Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Gauthier, M. K.
(Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Coss, J. R.
(Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Date Acquired
September 5, 2013
Publication Date
May 15, 1985
Subject Category
Solid-State Physics
Report/Patent Number
JPL-PUB-85-47
NAS 1.26:176196
NASA-CR-176196
Report Number: JPL-PUB-85-47
Report Number: NAS 1.26:176196
Report Number: NASA-CR-176196
Accession Number
85N35795
Funding Number(s)
PROJECT: RTOP 323-51-45-00-02
CONTRACT_GRANT: NAS7-918
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available