Effects of leakage through clearance seals on the performance of a 10 K Stirling-cycle refrigeratorThe use of clearance seals is essential to achieve long life, wear free operation of Stirling cycle cryogenic refrigerators. The effect of leakage through clearance seals on the performance of such a refrigerator operating at temperatures ranging from 20 K down to 10 K was determined. The ability of a Stirling cycle refrigerator to achieve 10 K with clearance seals was successfully demonstrated. It is indicated that the leakage flow undergoes gap regeneration before reaching the cold expansion volume. A simple model of gap regeneration was used to estimate the regeneration loss due to the leakage flow. This regeneration process minimizes the loss in refrigerator performance caused by the clearance seal leakage. It is found that clearance seals remain effective down to a refrigeration temperature of 10 K.