Quantitative thermal characterization of thin platesThe principles of quantitative thermal testing of the mechanical integrity of platelike structures are discussed. In this technique, a scanned laser pulse is used to inject a thermal pattern in a sample, and a thermal IR imager is used to document the evolution of the pattern subsequent to injection. The measurements are remote, noncontacting, and one-sided, and the algorithms used to obtain diffusivity are all emissivity-independent. The results yielded by application of the three analytical techniques, used to obtain diffusivity values from the image data on stainless steel, a graphite-epoxy composite, brass, and aluminum 2024 samples, are presented.
Document ID
19870023477
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Welch, C. S. (NASA Langley Research Center Hampton; College of William and Mary, Williamsburg, VA, United States)
Heath, D. M. (NASA Langley Research Center Hampton, VA, United States)
Winfree, W. P. (NASA Langley Research Center Hampton, VA, United States)