Ignition delay times of cyclopentene oxygen argon mixturesThe oxidation of cyclopentene was studied experimentally to expand the database on pyrolysis and the reaction products of five carbon unsaturated ring compounds. Pyrolysis was carried out in a single-pulse shock tube. Data were gathered on the shock speed, wall pressure, and reflected shock temperatures. Four different mixtures of C5H8, O2 and Ar, ranging from 0.25-1 percent cyclopentene and 1.75-7 percent O2, were examined in 76 different trials. The data showed a shock temperature range of 1323-1816 K and a pressure range of 1.67-7.36 atmospheres. A student-t test analysis of the results led to definition of an ignition delay equation accurate to the 2-sigma level.
Document ID
19870025328
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Burcat, A. (Technion - Israel Institute of Technology Haifa, United States)
Snyder, C. (Technion - Israel Inst. of Tech. Haifa, Israel)
Brabbs, T. (NASA Lewis Research Center Cleveland, OH, United States)