Phase calibration generatorA phase calibration system was developed for the Deep Space Stations to generate reference microwave comb tones which are mixed in with signals received by the antenna. These reference tones are used to remove drifts of the station's receiving system from the detected data. This phase calibration system includes a cable stabilizer which transfers a 20 MHz reference signal from the control room to the antenna cone. The cable stabilizer compensates for delay changes in the long cable which connects its control room subassembly to its antenna cone subassembly in such a way that the 20 MHz is transferred to the cone with no significant degradation of the hydrogen maser atomic clock stability. The 20 MHz reference is used by the comb generator and is also available for use as a reference for receiver LO's in the cone.
Document ID
19880009401
Acquisition Source
Legacy CDMS
Document Type
Reprint (Version printed in journal)
Authors
Sigman, E. H.
(Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Date Acquired
September 5, 2013
Publication Date
February 15, 1988
Publication Information
Publication: The Telecommunications and Data Acquisition Report
Subject Category
Instrumentation And Photography
Accession Number
88N18785
Funding Number(s)
PROJECT: RTOP 314-40-51-32-09
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.