Boiling oxygen experimental studies in an electrically heated tubeAn experimental study was made of subcooled flow boiling with LOX; data were obtained with thermocouples attached to the walls of an electrically heated tube through which the LOX flowed. Pressure levels in the tube ranged from 200 psia to supercritical values, and the cooling level varied from the saturated condition to 50 F. Reynolds numbers ranged from 1.5 x 10 to 3.5 x 10 to the 5th. Results show that an increase in either pressure, subcooling level, or Reynolds number produces an increase in the film boiling heat transfer coefficient. Data for this range of parameters were found to correlate in terms of the Stanton number vs (T sub w - T sub s)/(T sub s - T sub b), where T is temperature, w is the wall, s is the saturated condition, and b is the bulk.
Document ID
19880060800
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Peroulias, C. (Rockwell International Corp. Canoga Park, CA, United States)
Pidcoke, L. H. (Rockwell International Corp. Canoga Park, CA, United States)
Schwartz, S. H. (Rockwell International Corp. Canoga Park, CA, United States)
Mussell, D. E. (Rockwell International Corp. Rocketdyne Div., Canoga Park, CA, United States)
Date Acquired
August 13, 2013
Publication Date
July 1, 1988
Subject Category
Fluid Mechanics And Heat Transfer
Report/Patent Number
AIAA PAPER 88-2842Report Number: AIAA PAPER 88-2842