NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Gas permeation measurements on small polymer specimensMass spectrometry was used to measure oxygen and nitrogen permeabilities while polarography was used to measure oxygen permeabilities for several contact lens materials. Applicable sample holders were designed and fabricated to accommodate curved and flat specimens. A prepared standard was used to calibrate the mass spectrometric analyses. The oxygen permeability values determined by mass spectrometry were significantly greater than those determined by polarography. This was attributed to the phase boundary phenomena and the limiting oxygen permeance of water inherent in the polarographic technique. Polarographic values determined were in good agreement with proprietary values obtained by polarography, with the exception of one material.
Document ID
19890004238
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Burns, Karen S.
(Old Dominion Univ. Norfolk, VA, United States)
Vannorman, John D.
(Old Dominion Univ. Norfolk, VA, United States)
Date Acquired
September 5, 2013
Publication Date
February 1, 1988
Subject Category
Nonmetallic Materials
Report/Patent Number
NASA-CR-182439
NAS 1.26:182439
Report Number: NASA-CR-182439
Report Number: NAS 1.26:182439
Accession Number
89N13609
Funding Number(s)
CONTRACT_GRANT: NAS1-17993
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available