NASA powered lift facility internally generated noise and its transmission to the acoustic far fieldNoise tests of NASA Lewis Research Center's Powered Lift Facility (PLF) were performed to determine the frequency content of the internally generated noise that reaches the far field. The sources of the internally generated noise are the burner, elbows, valves, and flow turbulence. Tests over a range of nozzle pressure ratios from 1.2 to 3.5 using coherence analysis revealed that low frequency noise below 1200 Hz is transmitted through the nozzle. Broad banded peaks at 240 and 640 Hz were found in the transmitted noise. Aeroacoustic excitation effects are possible in this frequency range. The internal noise creates a noise floor that limits the amount of jet noise suppression that can be measured on the PLF and similar facilities.
Document ID
19890007511
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Huff, Ronald G.
(Sverdrup Technology, Inc. Cleveland, OH, United States)
Date Acquired
September 5, 2013
Publication Date
November 1, 1988
Subject Category
Research And Support Facilities (Air)
Report/Patent Number
NAS 1.26:182217
E-4474
NASA-CR-182217
Report Number: NAS 1.26:182217