Ground-based plasma contactor characterizationThis paper presents recent NASA Lewis Research Center plasma contactor experimental results, as well as a description of the plasma contactor test facility. The operation of a 24-cm-diameter plasma source with hollow cathode was investigated in the 'ignited-mode' regime of electron current collection from 0.1 to 7.0 A. These results are compared to those obtained with a 12-cm plasma source. Full two-dimensional plasma potential profiles were constructed from emissive probe traces of the contactor plume. The experimentally measured dimensions of the plume sheaths were then compared to those theoretically predicted, using a model of a spherical double sheath. Results are consistent for currents up to approximately 1.0 A. For currents above 1.0 A, substantial deviations from theory occur. These deviations are due to sheath asphericity, and, possibly, volume ionization in the double-sheath region.
Document ID
19890055988
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Patterson, Michael J. (NASA Lewis Research Center Cleveland, OH, United States)
Aadland, Randall S. (NASA Lewis Research Center Cleveland, OH, United States)
Date Acquired
August 14, 2013
Publication Date
January 1, 1988
Subject Category
Plasma Physics
Meeting Information
Meeting: Intl. Conference on Space Tethers for Science in the Space Station Era