Model 0A wind turbine generator FMEAThe results of Failure Modes and Effects Analysis (FMEA) conducted for the Wind Turbine Generators are presented. The FMEA was performed for the functional modes of each system, subsystem, or component. The single-point failures were eliminated for most of the systems. The blade system was the only exception. The qualitative probability of a blade separating was estimated at level D-remote. Many changes were made to the hardware as a result of this analysis. The most significant change was the addition of the safety system. Operational experience and need to improve machine availability have resulted in subsequent changes to the various systems which are also reflected in this FMEA.
Document ID
19900002718
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Klein, William E. (NASA Plum Brook Reactor Facility Sandusky, OH., United States)
Lalli, Vincent R. (NASA Lewis Research Center Cleveland, OH, United States)
Date Acquired
September 6, 2013
Publication Date
October 1, 1989
Subject Category
Quality Assurance And Reliability
Report/Patent Number
NAS 1.15:102378DOE/NASA/20370-23E-5117NASA-TM-102378Report Number: NAS 1.15:102378Report Number: DOE/NASA/20370-23Report Number: E-5117Report Number: NASA-TM-102378
Meeting Information
Meeting: 1990 Annual Reliability and Maintainability Symposium