NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Design and performance analysis of the CLAES Ne/CO2 cryostatThe design of the dual-stage Ne/CO2 cryostat, constructed for the Cryogenic Limb Array Etalon Spectrometer (CLAES) for the cooling, to their respective required operation temperatures, of the focal plane (to less than 15 K), spectrometer (to less than 30 K), telescope (to less than 150 K), and baffles (to less than 180 K) is described, and the cryostat's performance is analyzed. The results of this study show that the current cryostat will meet all sensor cooling requirements. The cryostat weighs 2276 lbs, of which 988 lbs are charged to the neon and 484 lbs are charged to the CO2. Schematic diagrams of the CLAES cooler/sensor and of the external plumbing are presented together with the test data.
Document ID
19900024234
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Naes, L. G.
Horsley, W. J.
Ngai, C. S.
Read, D. C.
Nast, T. C.
Date Acquired
August 14, 2013
Publication Date
January 1, 1989
Subject Category
Engineering (General)
Meeting Information
Meeting: Cryogenic Optical Systems and Instruments III
Location: San Diego, CA
Country: United States
Start Date: August 17, 1988
End Date: August 19, 1988
Sponsors: SPIE
Accession Number
90A11289
Funding Number(s)
CONTRACT_GRANT: NAS5-27752
Distribution Limits
Public
Copyright
Other

Available Downloads

There are no available downloads for this record.
No Preview Available