A numerical parametric study of a scramjet inlet in a Mach 6 arc heated test facilityA numerical study of the NASA Langley Arc Heated Scramjet Test Facility (AHSTF) is reported. The facility test flow through the Mach 6 quasi-two-dimensional nozzle was computed, and the flow through the Langley parametric inlet was calculated using different regions of the computed facility nozzle exit flow as inflow, exploring in more detail the effect of boundary layer ingestion on inlet performance. The potential advantage of using a quasi-two-dimensional nozzle in the Langley AHSTF versus the square cross-sectioned nozzle currently used for Scramujet engine tests is explored in terms of resulting inlet performance.
Document ID
19900032841
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Sekar, B. (Vigyan Research Associates, Inc. Hampton, VA, United States)
Thomas, S. (NASA Langley Research Center Hampton, VA, United States)
Srinivasan, S. (A.S.&M., Inc. Hampton, VA, United States)
Date Acquired
August 14, 2013
Publication Date
January 1, 1990
Subject Category
Aerodynamics
Report/Patent Number
AIAA PAPER 90-0531Report Number: AIAA PAPER 90-0531