An improved high power hybrid capillary pumped loopIn order to improve performance testing, NASA's High-Power Spacecraft Thermal Management system has been modified through (1) an augmentation of heat-dissipation capacity of the condenser sink for steady-state high power operation, (2) the addition of more pressure transducers for pressure-drop monitoring in various system components, (3) the installation of pressure-contact thermocouples on the evaporators to measure heating surface temperature, (4) the provision of a coolant loop to one of the evaporator plates, (5) the placing of a transient fluid flow-monitoring load cell in the reservoir, and (6) the reorientation of the reservoir to reduce compressed vapor effects. The system is now capable of 10 hours of continuous capillary mode operation at an input power level of 20 kW.
Document ID
19900040473
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Ku, Jentung (OAO Corp. Greenbelt, MD, United States)
Kroliczek, Edward J. (OAO Corp. Greenbelt, MD, United States)
Mccabe, Michael E., Jr. (NASA Goddard Space Flight Center Greenbelt, MD, United States)