Recent experience with elevated-temperature foil strain gages with application to thin-gage materialsThe effects of thin-gage materials on high-temperature strain measurements are discussed. Apparent strain test were performed using facesheet coupons, honeycomb coupons, and the panel with strain gages in an installed condition. The apparent strain results differed in each of the cases. The apparent strain curves from the panel tests are expected to provide the best correlation with analysis, assuming that the thermal strains are insignificant or that the thermal strains derived from the analysis of the apparent strain test performed on the panel can be used to correct the apparent strain curves.
Document ID
19900057437
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Hudson, Larry D. (NASA Flight Research Center Edwards, CA, United States)
Date Acquired
August 14, 2013
Publication Date
January 1, 1989
Subject Category
Instrumentation And Photography
Meeting Information
Meeting: Hostile Environments and High Temperature Measurements