Transient cryogenic liquid discharge in normal and micro-gravityTransient discharge of liquid cryogens from partially filled tanks under microgravity is considered. The discharge is made to a low-pressure site through a straight tube. The ultimate objective of the study is to predict the transient mass flow rate. In addition, the pressure history in the tank is of interest, since the pressure falls below the triple point toward the end of the dump, causing solidification in the tank and/or the discharge line. As first steps, experiments have been performed in normal gravity and attempts are made to predict the transient rate and pressure history under this condition. Experiments are performed with liquid nitrogen dumped to sites with pressures below the triple point. Homogeneous equilibrium and nonequilibrium two-phase critical flow models are compared to the experimental results. Equilibrium and nonequilibrium tank pressure history models are also compared to experimental data.