A high resolution electro-optical displacement measurement systemAn improved electrooptical system has been developed to sense wind tunnel model position. The original system using 25.6 mm, 1024-element linear photodiode arrays (PDAs) is being successfully used at a NASA wind tunnel but has a limited range. A new two-channel system using 61.44 mm, 4096-element PDAs has been developed to double the range of vertical and pitch measurement and increase the resolution by 60 percent. The PDAs are illuminated by expanding the beam of a single low power helium neon laser into a collimated sheet of light. An object placed in front of the two parallel PDAs produces a shadow on the array apertures which determines the object's position or size. The system has an overall precision of 12.7 microns and + or - 0.015 degrees in linear and angular measurements.