NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Radiation test results on TK 1024 CCDsResults are presented from tests on TK 1024 CCDs with a multipinned phase (MPP) implant built into an experiental mask set. The average dark current as a function of temperature increased by a factor of about 3 for the 5 krads of gammas, which is a 10-fold increase for the extra 2 krads of protons. Histograms of the dark current show two types of dark current, an average level change, and dark current spikes.
Document ID
19910061383
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Delamere, Alan
(Ball Corp. Boulder, CO, United States)
Murata-Seawalt, Debbie
(Ball Corp. Boulder, CO, United States)
Orbock, Jeff
(Ball Aerospace Sytems Group Boulder, CO, United States)
Blouke, Morley
(Tektronix, Inc. Beaverton, OR, United States)
Fowler, Walt
(Ball Corp. Boulder, CO, United States)
Rebar, Frank
(NASA Goddard Space Flight Center Greenbelt, MD, United States)
Date Acquired
August 14, 2013
Publication Date
January 1, 1990
Subject Category
Electronics And Electrical Engineering
Accession Number
91A46006
Distribution Limits
Public
Copyright
Other

Available Downloads

There are no available downloads for this record.
No Preview Available