Long term integrity for space station power systemsA study was made of the High Temperature Design Codes ASME N47, British R5, and the French RCC-MR Rules. It is concluded that all these codes provide a good basis of design for space application. The new British R5 is the most complete since it deals with the problem of defects. The ASME N47 was subjected longer to practical application and scrutiny. A draft code is introduced, and a proposed draft for high temperature design in which attempts were made to identify gaps and improvements is suggested. The design is limited by creep characteristics. In these circumstances, life is strongly affected by the selected value of the factor of safety. The factor of safety of primary loads adopted in the codes is 1.5. Maybe a lower value of 1.25 is permissible for use in space. Long term creep rupture data for HAYNES 188 is deficient and it is suggested that extrapolation methods be investigated.
Document ID
19920009684
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Leckie, F. A.
(California Univ. Santa Barbara, CA, United States)
Marriott, D. L.
(Illinois Univ. Urbana-Champaign., United States)
Date Acquired
September 6, 2013
Publication Date
January 1, 1991
Subject Category
Spacecraft Propulsion And Power
Report/Patent Number
NAS 1.26:189910
NASA-CR-189910
Report Number: NAS 1.26:189910
Report Number: NASA-CR-189910
Accession Number
92N18926
Funding Number(s)
CONTRACT_GRANT: NAG3-1218
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available