High accuracy fuel flowmeter. Phase 2C and 3: The mass flowrate calibration of high accuracy fuel flowmetersA facility for the precise calibration of mass fuel flowmeters and turbine flowmeters located at AMETEK Aerospace Products Inc., Wilmington, Massachusetts is described. This facility is referred to as the Test and Calibration System (TACS). It is believed to be the most accurate test facility available for the calibration of jet engine fuel density measurement. The product of the volumetric flow rate measurement and the density measurement, results in a true mass flow rate determination. A dual-turbine flowmeter was designed during this program. The dual-turbine flowmeter was calibrated on the TACS to show the characteristics of this type of flowmeter. An angular momentum flowmeter was also calibrated on the TACS to demonstrate the accuracy of a true mass flowmeter having a 'state-of-the-art' design accuracy.
Document ID
19920010533
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Craft, D. William
(Ametek, Inc. Wilmington, MA, United States)
Date Acquired
September 6, 2013
Publication Date
February 1, 1992
Subject Category
Instrumentation And Photography
Report/Patent Number
NASA-CR-187108
NAS 1.26:187108
Report Number: NASA-CR-187108
Report Number: NAS 1.26:187108
Accession Number
92N19775
Funding Number(s)
CONTRACT_GRANT: NAS3-24357
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.