Precision intercomparisons between MSU channel 2 and radiosonde data over the United StatesResults are presented of an intercomparison between MSU channel 2 Tb and radiosonde data taking both oxygen and water vapor absorption into account. A total of 45 stations covering most of the central and eastern U.S. were included. Precise comparisons (to 0.1 C or better) between MSU Tb and radiosonde-calculated Tb were found to be possible with large numbers of stations and long averaging periods (many months), although they are not sufficient in number to address the previously documented monthly precision of 0.01 C from satellite-satellite intercomparisons. The MSU channel 2 does not have a 1:1 response to atmospheric temperature variations; the response averages about 92 percent. No evidence was found to suggest that procedural or hardware changes in the U.S. radiosonde system have caused any widespread biases between 1980 and 1986.