Operation and design considerations for unsteady data acquisition with PC-based systems in high Reynolds number hypersonic flowfieldsOperation and design considerations for personal-computer-based data acquisition are analyzed, and a system is created that is portable, inexpensive, and capable of high-frequency response. This system performed well when given an extensive analysis of the characteristics of the radio-frequency noise in the test environment. The system architecture is well-suited for support of high-frequency data acquisition from both pressure transducers and high-frequency-response thermocouple gauges. As configured, the system provides a data resolution of approximately 0.09 psia and 0.56 F. Considering the constraints placed upon this design, this data resolution is acceptable. The $5000 budget did require use of an existing PC and rental of signal-conditioning equipment.
Document ID
19920041186
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Flanagan, M. J., Jr. (Ohio State University Columbus, United States)
Date Acquired
August 15, 2013
Publication Date
January 1, 1992
Subject Category
Research And Support Facilities (Air)
Report/Patent Number
AIAA PAPER 92-0204Report Number: AIAA PAPER 92-0204