Detection of stratospheric ozone trends by ground-based microwave observationsWe present an assessment of the trend detection capabilities of ground-based microwave measurements of ozone, focusing on the 20-60 km region. Uncertainty due to variable forward model and calibration errors is 3-5 percent; due to temperature profile errors, 1-2 percent; and due to spectral measurement errors, 1-3 percent. The measurement resolution is 8-10 km below 40 km, and increases to 17 km at 60 km. The net error for trend detection is 4-6 percent. Comparison with other measurements suggests interannual variations can be measured to 3-5 percent. We conclude a trend of 0.5 percent per year would be detected in about 10 years.
Document ID
19930047403
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Connor, Brian J. (NASA Langley Research Center Hampton, VA, United States)
Parrish, Alan (Massachusetts Univ. Amherst, United States)
Tsou, J. J. (Lockheed Engineering and Sciences Co. Hampton, VA, United States)
Date Acquired
August 16, 2013
Publication Date
January 1, 1991
Publication Information
Publication: In: Remote sensing of atmospheric chemistry; Proceedings of the Meeting, Orlando, FL, Apr. 1-3, 1991 (A93-31376 11-35)
Publisher: Society of Photo-Optical Instrumentation Engineers