Topex Microwave Radiometer thermal control - Post-system-test modifications and on-orbit performanceThe Topex Microwave Radiometer has had an excellent thermal performance since launch. The instrument, however, went through a hardware modification right before launch to correct for a thermal design inadequacy that was uncovered during the spacecraft thermal vacuum test. This paper reports on how the initially obscure problem was tracked down, and how the thermal models were revised, validated, and utilized to investigate the solution options and guide the hardware modification decisions. Details related to test data interpretation, analytical uncertainties, and model-prediction vs. test-data correlation, are documented. Instrument/spacecraft interface issues, where the problem originated and where in general pitfalls abound, are dealt with specifically. Finally, on-orbit thermal performance data are presented, which exhibit good agreement with flight predictions, and lessons learned are discussed.
Document ID
19930062497
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Lin, Edward I. (JPL Pasadena, CA, United States)
Date Acquired
August 16, 2013
Publication Date
July 1, 1993
Subject Category
Spacecraft Instrumentation
Report/Patent Number
AIAA PAPER 93-2743Report Number: AIAA PAPER 93-2743