A bi-directional two-phase/two-phase heat exchangerThis paper describes the design and test of a heat exchanger that transfers heat from one two-phase thermal loop to another with very small drops in temperature and pressure. The heat exchanger condenses the vapor in one loop while evaporating the liquid in the other without mixing of the condensing and evaporating fluids. The heat exchanger is bidirectional in that it can transfer heat in reverse, condensing on the normally evaporating side and vice versa. It is fully compatible with capillary pumped loops and mechanically pumped loops. Test results verified that performance of the heat exchanger met the design requirements. It demonstrated a heat transfer rate of 6800 watts in the normal mode of operation and 1000 watts in the reverse mode with temperature drops of less than 5 C between two thermal loops.
Document ID
19930062590
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Ku, Jentung (NASA Goddard Space Flight Center Greenbelt, MD, United States)
Ottenstein, Laura (NASA Goddard Space Flight Center Greenbelt, MD, United States)
Date Acquired
August 16, 2013
Publication Date
July 1, 1993
Subject Category
Fluid Mechanics And Heat Transfer
Report/Patent Number
AIAA PAPER 93-2852Report Number: AIAA PAPER 93-2852